{"product_id":"siemens-50-amp-double-pole-type-qe-ground-fault-equipment-protection-circuit-breaker","title":"Siemens 50 Amp Double Pole Type QE Ground Fault Equipment Protection Circuit Breaker","description":"\u003ch1\u003e50 Amp Type QE GFCI Circuit Breaker\u003c\/h1\u003e\n    \u003cp\u003e\u003cstrong\u003eThe Siemens 50 Amp Double Pole Type QE GFCI Circuit Breaker is designed to protect equipment from damaging line-to-ground faults, ensuring reliable safety and performance. With a 30 mA ground fault interruption, it de-energizes the circuit quickly, safeguarding both devices and users.\u003c\/strong\u003e\u003c\/p\u003e\n    \n    \u003chr\u003e\n    \u003ch2\u003eKey Features:\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLoad Center Ready:\u003c\/strong\u003e Seamlessly integrates with your existing electrical panel systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble Pole Design:\u003c\/strong\u003e Offers robust protection for circuits with 120\/240V requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30 mA GFCI Protection:\u003c\/strong\u003e Safeguards equipment by detecting and responding to ground faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-in Design:\u003c\/strong\u003e Ensures easy installation with standard 1-inch per pole format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed:\u003c\/strong\u003e Meets rigorous safety standards for reliable use in various environments.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \n    \u003chr\u003e\n    \u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\n    \u003ctable\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n                \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePigtail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterruption Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGFCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Amperage (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Weight (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.07 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications and Listings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Depth (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Height (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Width (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n    \u003chr\u003e\n    \u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: How do I install this Siemens circuit breaker?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It's a plug-in design that fits in standard 1-inch per pole load centers. Always consult with a professional electrician for any installation to ensure safety and compliance with local codes.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What is the main function of this GFCI breaker?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e This breaker detects ground faults and interrupts power, protecting equipment from potential electrical damage.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Can this breaker be used in residential settings?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is suitable for both residential and commercial settings, offering protection for any environment where ground fault protection is needed.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Does this breaker need regular maintenance?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Typically, GFCI breakers do not require regular maintenance, but periodic testing is recommended to ensure proper functioning.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Is it compatible with any load center brand?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It's primarily designed to fit Siemens load centers but can be compatible with others; consult the circuit breaker's manual or contact Siemens for details.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003ch2\u003eUnyielding Safety Meets Elegant Design\u003c\/h2\u003e\n    \u003cp\u003e\n                                        Transform any environment into a secure haven with the Siemens 50 Amp GFCI Circuit Breaker. Beyond its technical prowess, this breaker embodies precision engineering that seamlessly integrates with your electrical infrastructure. Harness the elegant efficiency of its double pole design while ensuring each corner of your space is enveloped in exemplary safety. This is more than a circuit breaker; it's a cornerstone of intelligent, luxurious living.\n                                        \u003c\/p\u003e\n    \u003chr\u003e\n    \u003cp\u003e\u003cstrong\u003eExplore the Siemens 50 Amp GFCI Circuit Breaker to ensure your equipment's safety with industry-leading protection technology.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003ca href=\"https:\/\/superarbor.io\/cdn\/shop\/files\/83cf8be2-9deb-4fe1-9e10-8970d73006bc_e293a4d9-517e-49b2-941b-1ba844419232.pdf?v=1735283115\" target=\"_blank\"\u003eWarranty\u003c\/a\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49005996507350,"sku":"QE250","price":177.78,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0778\/5244\/2838\/files\/siemens-circuit-breakers-qe250-64_1000_cef2637d-7b67-436a-9244-23f0d1d48620.jpg?v=1783708397","url":"https:\/\/buildsupplyus.myshopify.com\/products\/siemens-50-amp-double-pole-type-qe-ground-fault-equipment-protection-circuit-breaker","provider":"Buildsupply","version":"1.0","type":"link"}