{"product_id":"huntsman-building-solutions-heatlok-r-hfo-high-lift-closed-cell-spray-foam-insulation-set-hs200-00wdu","title":"Huntsman Building Solutions Heatlok® HFO High Lift Closed-Cell Spray Foam Insulation Set (HS200-00WDU)","description":"\u003ch1\u003eHeatlok HFO High Lift Closed-Cell Spray Foam Insulation\u003c\/h1\u003e\n    \u003cp\u003e\u003cstrong\u003eHeatlok® HFO High Lift is a closed-cell spray foam insulation formulated to deliver an aged R-value of about 7.4 per inch while allowing up to a 6.5 in. lift per pass to help meet ceiling code faster. It leverages Honeywell Solstice® HFO technology for ultra-low global warming potential and is designed for strong adhesion, good yield, and efficient application.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eKey Features:\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHigh R-Value Performance:\u003c\/strong\u003e Aged thermal resistance of ~R-7.4 per inch (depending on installed thickness).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Lift Application:\u003c\/strong\u003e Sprays up to 6.5 in. per pass to reduce labor time and speed code compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture \u0026amp; Vapor Control:\u003c\/strong\u003e Tested WRB performance and functions as a Class II vapor retarder at 2 in. thickness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode \u0026amp; Resiliency Credentials:\u003c\/strong\u003e NFPA 285 tested behind multiple claddings and meets FEMA Class 5 flood damage resistance requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Impact Formulation:\u003c\/strong\u003e Uses Solstice® HFO blowing agent technology (GWP 1) and is GREENGUARD Gold certified (low VOC).\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\u003cstrong\u003ePlease check the Product Data Sheet \u003ca href=\"https:\/\/superarbor.io\/cdn\/shop\/files\/20.00063-Heatlok_HFO_High_Lift-TDS-V6-DIGITAL.pdf?v=1766980676\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eHere\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\n    \u003ctable\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n                \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHEATLOK HFO HIGH LIFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-cell spray foam insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAged thermal resistance (R-value)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.4 per inch (depending on installed thickness)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum lift per pass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVapor retarder rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass II vapor retarder at 2 in. thickness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWater-resistive barrier (WRB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTested water-resistant barrier (WRB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNFPA 285\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTested and approved behind multiple claddings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGREENGUARD certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGREENGUARD Gold Certified (low VOC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eASTM C1029\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType II (~25 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEMA flood damage resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets Class 5 FEMA (Flood Damage Resistance Requirements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABAA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABAA evaluated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlowing agent technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell Solstice® HFO Liquid Blowing Agent technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGlobal warming potential (GWP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 (per manufacturer description)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15–100°F (-9–38°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEstimated yield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4500–5000 bd. ft. per set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eASTM E84 flame spread index\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n    \u003chr\u003e\n    \u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What R-value does Heatlok HFO High Lift provide?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It provides an aged thermal resistance of approximately R-7.4 per inch (depending on installed thickness).\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: How thick can I spray in one pass?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Up to a maximum 6.5 in. lift per pass.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Is it considered a vapor retarder?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Yes—at 2 in. thickness it is listed as a Class II vapor retarder.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What temperature range can it be applied in?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e 15–100°F (-9–38°C).\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What makes it more environmentally friendly than traditional closed-cell foam?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It leverages Solstice® HFO blowing agent technology with a GWP of 1 (99.9% lower than traditional blowing agents, per the manufacturer description).\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003ch2\u003eInvisible insulation, unmistakable comfort.\u003c\/h2\u003e\n    \u003cp\u003eThink of Heatlok® HFO High Lift as the quiet architecture behind a beautifully finished room—sealing, insulating, and elevating comfort without asking for attention. Its standout advantage is the high-lift application, letting performance build quickly while supporting a cleaner, more efficient envelope. Use it to create calm, consistent temperatures in vaulted ceilings or unvented attic conversions where comfort can feel elusive. It’s the kind of behind-the-walls upgrade that makes everyday living feel effortlessly luxe.\u003c\/p\u003e\n    \n    \u003chr\u003e\n    \u003cp\u003e\u003cstrong\u003eUpgrade your building envelope with Heatlok® HFO High Lift for faster high-R insulation and a tighter, more resilient seal.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Huntsman Building Solutions","offers":[{"title":"Default Title","offer_id":49006726250710,"sku":"HS200-00WDU","price":305.55,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0778\/5244\/2838\/files\/2925__22710.1735851356.jpg?v=1783712257","url":"https:\/\/buildsupplyus.myshopify.com\/products\/huntsman-building-solutions-heatlok-r-hfo-high-lift-closed-cell-spray-foam-insulation-set-hs200-00wdu","provider":"Buildsupply","version":"1.0","type":"link"}