{"product_id":"eaton-br-2-30-amp-2-pole-bq-independent-trip-quad-circuit-breaker","title":"Eaton BR 2-30 Amp 2 Pole BQ (Independent Trip) Quad Circuit Breaker","description":"\u003ch1\u003eEaton BR Quad Circuit Breaker with Independent Trip\u003c\/h1\u003e\n    \u003cp\u003e\u003cstrong\u003eThe Eaton BR Quad Circuit Breaker is engineered for ultimate protection and versatility in both residential and commercial applications. Featuring a 2-30 Amp dual pole configuration, its independent trip technology and rejection tab feature ensure safe and reliable power management, fitting seamlessly in BR load centers. Ideal for creating four circuits in two spaces, this breaker supports demanding electrical setups with ease.\u003c\/strong\u003e\u003c\/p\u003e\n    \n    \u003chr\u003e\n    \u003ch2\u003eKey Features:\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndependent Trip Technology:\u003c\/strong\u003e Allows for safer, controlled circuit interruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuad Configuration:\u003c\/strong\u003e Creates four circuits using just two panel spaces, optimizing load center use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Support:\u003c\/strong\u003e Handles 120\/240V circuits, ideal for comprehensive electrical needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Constructed to meet UL, ANSI, and CSA standards for quality assurance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Compatibility:\u003c\/strong\u003e Designed for use with BR-type load centers, including Westinghouse and Bryant.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\u003cstrong\u003ePlease check the Product Data Sheet \u003ca href=\"https:\/\/superarbor.io\/cdn\/shop\/files\/16cf66e8-263e-4f8b-931f-aea06afe8822.pdf?v=1735283004\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eHere\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\n    \u003ctable\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n                \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTandem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterruption Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Distribution Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo Additional Features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Weight (lb.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.79 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications and Listings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI Certified,CSA Listed,UL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 years per the Warranty Policy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Depth (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.884 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Height (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.105 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Width (in.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.97 in\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n    \u003chr\u003e\n    \u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: How does the independent trip feature work?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e The independent trip feature allows each circuit to trip separately in case of overload or faults, ensuring optimal control and safety.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Can this circuit breaker be used in any brand's load center?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e This breaker is designed specifically for BR type load centers and is compatible with brands like Westinghouse, Challenger, and Bryant.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What are the installation requirements for this circuit breaker?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Ensure the panel has notched bus stabs to accommodate the rejection clip, and follow standard installation procedures for BR load centers.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Is this breaker suitable for high-demand applications?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Yes, it supports circuits up to 240 volts and 30 amps, making it suitable for various residential and light commercial applications.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What is the significance of the rejection tab feature?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e The rejection tab ensures the breaker is correctly matched to compatible panel slots, preventing improper installation.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003ch2\u003eEmpower Your Electrical Design with Confidence\u003c\/h2\u003e\n    \u003cp\u003e\n                                        Elevate the functionality and safety of your electrical spaces with the Eaton BR Quad Circuit Breaker. As a crucial element in sophisticated power management, its independent trip mechanism enhances both reliability and performance. Install this breaker to create a seamless, powerful electrical narrative in any professional or residential setting. In the world of elegant, efficient living, the Eaton Circuit Breaker is your go-to for assured luxury and safety.\n                                        \u003c\/p\u003e\n    \u003chr\u003e\n    \u003cp\u003e\u003cstrong\u003eEnsure robust power management in your projects; upgrade to the Eaton BR Quad Circuit Breaker today to enhance safety and efficiency.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003ca href=\"https:\/\/superarbor.io\/cdn\/shop\/files\/4391700f-0ecf-4979-bd61-191cbd7a8abd.pdf?v=1735283007\" target=\"_blank\"\u003eWarranty\u003c\/a\u003e\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":49005965377750,"sku":"BQ230230","price":29.93,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0778\/5244\/2838\/files\/eaton-circuit-breakers-bq230230-64_1000_d62d85fb-91d9-4819-8a48-e4d976ec8e75.jpg?v=1783708177","url":"https:\/\/buildsupplyus.myshopify.com\/products\/eaton-br-2-30-amp-2-pole-bq-independent-trip-quad-circuit-breaker","provider":"Buildsupply","version":"1.0","type":"link"}